(DOMIcondens HE 26 C, OPTIMAX HE PLUS 31C, OPTIMAX HE PLUS 38C).


 

A01     Ignition error – possible electrode fault or power too low, no gas or excessive condensate level
A02     Electrode or card error
A03     Heating sensor damaged, no water circulation or air in system
F04     Wrong card parameter setting
F05     Air pressure switch contact error – wrong flue baffle obstructed or not correctly sized
A06     No flame after the ignition phase – low pressure in gas system burner minimum pressure setting
F07     Air pressure switch error – contacts closed on activation of fan
A09     Gas valve error – wiring could be disconnected or error with gas valve
F10     Delivery sensor error, sensor damaged wiring shorted or disconnected
F11     Domestic hot water (DHW) sensor error – sensor damaged, wiring shorted or disconnected
A15     Fault F05 generated 5 times within the last 24 hours – possible error with the air pressure switch
A16     Gas valve error – wiring disconnected or faulty gas valve
A23     Card parameter error – possibly wrong card parameter setting
A24     Card parameter error – possibly wrong card parameter setting
F34     Supply voltage under 170V – electric mains error
F35     Faulty mains frequency – electric mains error
F37     Error with system water pressure, possible pressure too low or water pressure switch is damaged
F43     Exchanger protection intervention – could be because no system water circulation or there’s air in the system
F50     Controller DBM23B error – controller could have an internal error
F51     Controller DBM23B error – controller could have an internal error 

----------------

 Codes d'erreur Ferroli Bluehelix Tech

Fault Code     System Behaviour     Possible cause
A01     No burner ignition     No gas or ignition – issue with detection electrode, faulty gas valve or insufficient gas supply pressure
A02     Flame signal present with burner off     Electrode error or PCB error
A05     Fan error     No 230V power supply or tachometric signal interrupted fan damaged or out of balance
A06     No flame after the ignition phase     Ionisation electrode fault – flame unstable or air/flue ducts obstructed or condensate trap or pipes blocked
F07 – F14 – A07     High flue gas temperature     The flue gas probe detects excessive temperature
F08 – A08     Overtemperature protection intervention     Heating sensor damaged – no water circulation in the system or air in the system
F09 – A09     Overtemperature protection intervention     Return sensor damaged – no water circulation in the system or air in the system
F10 – A10     Flow sensor error     Sensor damaged – wiring shorted or wiring disconnected
F11 – A11     Return sensor fault     Sensor damaged – wiring shorted or wiring disconnected
F12     DHW sensor error     Sensor damaged – wiring shorted or wiring disconnected
F13 – A13     Flue probe fault     Probe damaged – wiring shorted or wiring disconnected
A14     Flue extraction duct safety device intervention     Fault F07 generated 3 times in the last 24 hours
F34     Supply voltage under 170V     Electric mains trouble
F37     Incorrect system water pressure     Pressure too low – water pressure switch either damaged, blocked or not connected
F39     Optional external probe error     Probe damaged or wiring shorted – probe disconnected after activating the outside temperature mode
F41     Activation of maximum ELTA T protection     Heating sensor damaged, return sensor damaged, no water circulation as air in the system
F42 – A42     Sensor control protection activation     Heating sensor damaged, return sensor damaged or disconnected
F43     Exchanger protection intervention     No system water circulation – air in system
A23 – A24 – A26 – F15 – F20 – F21 – F40 – F47 – F50 – F51 – F53     Printed circuit board (PCB) parameter fault     Wrong PCB parameter setting
F56 – A56     Calibration error / calibration procedure not completed     Incorrect parameters electrode damaged or not correctly positioned
F61 – A61     Printed circuit board (PCB) AGC01 error     PCB AGC01 internal error
A54 – A55 – A63     Printed circuit board (PCB) AGC01 fault     PCB AGC01 fault
F67     –     Boiler chip card (BCC) service key connected
F68 – A68     Boiler chip card (BCC) service key fault     Error loading BCC service key file
A62     No communication between PCB and gas valve     PCB not connected – valve damaged, replace valve
A64     Maximum number of consecutive resets exceeded     Maximum number of consecutive resets exceeded
F66     –     Firmware not loaded successfully

-----------------------

Codes d'erreur du système Ferroli Modena HE

 Fault Code     System Behaviour
A01     No burner ignition – possible electrode error, defective gas valve or incorrect inlet gas pressure
A02     Flame detected with the burner off – electrode defective main board defective
A03     High limit protection – possible flow temperature sensor not active or incorrectly located, no system circulation
A04     Flue gas fault – fault F07 happened 3 times in the last 24 hours
A05     Fan error – tachometer signal interrupted for 1 hour or longer
A06     No flame after the ignition phase – electrode error, flame unstable, incorrect valve gas offset or flue gas circuit obstructed
A41     Flow sensor error – sensor disconnected
A42     Flow sensor error – sensor damaged
F07     High fume temperature – the exchanger probe detects an excessive temperature
F10     Flow sensor error – sensor damaged, short circuited, sensor damaged or wiring broken
F11     Return sensor error – t-sensor damaged, short circuited, sensor damaged or wiring broken
F13     Exchanger probe error – t-sensor damaged, short circuited, sensor damaged or wiring broken
F14     Flow sensor error – t-sensor damaged, short circuited, sensor damaged or wiring broken
F15     Fan problem – tachometer signal interrupted fan connection or damaged debris in fan. You need to check and clean fan debris
F34     Supply voltage under 170v – electric supply error
F35     Irregular mains frequency – electric supply problem
F37     Incorrect system water pressure error – possible sensor damaged or pressure too low
F43     Exchanger protection activation – no system circulation air in system
F52     Flow sensor – fault sensor damaged
A61     Controller ABM03B error – controller has an internal error
A62     No communication between controller and gas valve – controller not connected or valve damaged
A63 / A64 / F66     Controller ABM03B error – controller internal error 

---------------


Codes d'erreur Ferroli Modena HE Combi

 Fault Code   System Behaviour
A01    No burner ignition – possibly no gas, detection or ignition electrode fault, defective gas valve, incorrect inlet gas pressure
A02    Flame detected with the burner off – possibly caused by ionisation, defective electrode or main board defective. Check the printed circuit board (PCB) or ionizing electrode wiring
A03    High limit protection – flow temperature sensor not active, incorrectly located or no system circulation. Check the position of the flow sensor or check pump and radiator valves
A04

    Flue gas fault – could be because F07 happened 3 times in the last 24 hours – check the flue
A05    Fan problem – tachometer signal interrupted for 1 hour or longer – check the wiring and the fan
A06    No flame after ignition phase – possible causes: detection electrode fault, flame unstable, incorrect valve gas offset, flue gas circuit
A41    Flow sensor disconnected – check the correct positioning and operation of the flow sensors
A42    Flow sensor fault – sensor needs changing
F07    High fume temperature – the exchanger probe detects an excessive temperature for over 2 minutes – check the exchanger.
F10    Flow sensor fault – possible causes: sensor damaged, short circuited or wiring broken check the wiring
F11    Return sensor fault – sensor wiring shorted or broken – check the wiring
F12    Domestic hot water (DHW) sensor fault – sensor damaged, wiring shorted or wiring disconnected – check the wiring
F13    Exchange probe fault – wiring shorted or wiring broken – check wiring
F14    Fan problem – tachometer signal interrupted fan connection. Fan damaged or debris in fan – check the wiring, the fan and clean debris
F15    Supply voltage under 170v – electric supply problem – the electrical system needs checking
F34    Irregular mains frequency – possible electric supply problem – the electrical system needs checking
F35    Incorrect system water pressure – possible cause is pressure too low or sensor damaged – the system may need filling or check the sensor
F37    External probe fault sensor damaged or short circuited – check the wiring
F39    Exchanger protection activation – possibly caused by no system circulation, air in the system or sensor damaged
F43    Flow sensor fault – sensor damaged – sensor needs changing
F52    Controller 041049G0 fault – controller internal error
A61    No communication between controller and gas valve controller – could not be connected or valve damaged
A62    Controller 041049G – internal error
A63 / A64 / F66    Controller DBM12 fault 

 ----------

 Codes d'erreur de la chaudière arrêtée Ferroli

 DOMIcondens HE 26 C  

Chaudière OPTIMAX HE PLUS 31C  

Chaudière OPTIMAX HE PLUS 38C.

 Boilers   Fault Code   System Behaviour
DOMIcondens HE 26 C / OPTIMAX HE PLUS 31C    A01   No burner ignition
OPTIMAX HE PLUS 38C    A01   The burner fails to light
DOMIcondens HE 26 C / OPTIMAX HE PLUS 31C boiler / OPTIMAX HE PLUS 38C    A02   Flame present signal with burner off, possible electrical fault
DOMIcondens HE 26 C / OPTIMAX HE PLUS 31C boiler / OPTIMAX HE PLUS 38C    A03   Over temperature protection activation
DOMIcondens HE 26 C / OPTIMAX HE PLUS 31C    A04   Fume thermostat fault
OPTIMAX HE PLUS 38C    A04   Fume extraction duct safety device activation
DOMIcondens HE 26 C / OPTIMAX HE PLUS 31C    A05   Fan fault or fume pressure switch fault
OPTIMAX HE PLUS 38C    A05   Fan protection activated
DOMIcondens HE 26 C / OPTIMAX HE PLUS 31C boiler / OPTIMAX HE PLUS 38C    A06   No flame after the ignition phase
OPTIMAX HE PLUS 31C boiler / OPTIMAX HE PLUS 38C    F07   High fume temperature
DOMIcondens HE 26 C    F07   Card parameter
DOMIcondens HE 26 C    A09   Gas value fault
DOMIcondens HE 26 C / OPTIMAX HE PLUS 31C boiler / OPTIMAX HE PLUS 38C    F10   Delivery sensor 1 fault
DOMIcondens HE 26 C    F11   DHW sensor fault
OPTIMAX HE PLUS 31C boiler / OPTIMAX HE PLUS 38C    F11   Return sensor fault
OPTIMAX HE PLUS 31C boiler / OPTIMAX HE PLUS 38C    F13   Fume sensor fault
DOMIcondens HE 26 C / OPTIMAX HE PLUS 31C boiler / OPTIMAX HE PLUS 38C    F14   Delivery sensor 2 fault
OPTIMAX HE PLUS 31C boiler / OPTIMAX HE PLUS 38C    F15   Fan fault
DOMIcondens HE 26 C    A16   Gas valve fault
DOMIcondens HE 26 C    F20   Combustion control fault
DOMIcondens HE 26 C    A21   Poor combustion fail
DOMIcondens HE 26 C    A23   Set nominal system water pressure not reached within 4 minutes
DOMIcondens HE 26 C    A24   4 fillings within 24 hours
DOMIcondens HE 26 C / OPTIMAX HE PLUS 31C boiler / OPTIMAX HE PLUS 38C    A34   Supply voltage under 170V / 180V
DOMIcondens HE 26 C    A35   Faulty mains frequency
OPTIMAX HE PLUS 31C boiler / OPTIMAX HE PLUS 38C    A35   Mains frequency anomaly
DOMIcondens HE 26 C / OPTIMAX HE PLUS 31C boiler / OPTIMAX HE PLUS 38C    A37   Incorrect system water pressure
DOMIcondens HE 26 C / OPTIMAX HE PLUS 31C boiler / OPTIMAX HE PLUS 38C    A39   External probe fault
DOMIcondens HE 26 C / OPTIMAX HE PLUS 31C boiler / OPTIMAX HE PLUS 38C    A41   Sensor positioning
DOMIcondens HE 26 C / OPTIMAX HE PLUS 31C boiler / OPTIMAX HE PLUS 38C    F42   Heating sensor fault
DOMIcondens HE 26 C    A43   Exchange protection activation
DOMIcondens HE 26 C    A50   Gas valve fault
DOMIcondens HE 26 C    A51   Poor combustion fault
OPTIMAX HE PLUS 31C boiler / OPTIMAX HE PLUS 38C    A62   No communication between electronic controller and gas valve